2025–26 / Cooling & prototypes / Tested prototype

Sheetansh

A chilled dome cools the space around one seated hostel resident.

THE QUESTION

Sheetansh / DESIGN BRIEF

Can a student cool their desk without cooling the whole hostel room?

The Sheetansh team receives its second-place award in the Residential Cooling Retrofit challenge.First iteration of the Sheetansh rig with the dome suspended over a chair.Second iteration using a slotted metal rack with the cooling unit at its base.
Sheetansh / ENGINEERING JOURNAL01 / 03

Inspect the dome

CHAPTER 01

Inspect the dome

A chilled surface above the occupant draws heat from the body by radiation. A frame positions the surface around the working area.

The Sheetansh team receives its second-place award in the Residential Cooling Retrofit challenge.
CHAPTER 02

Trace the cooling loop

A vapour-compression chiller removes heat from circulating water. The team tested a duct to carry the rejected heat outside.

First iteration of the Sheetansh rig with the dome suspended over a chair.
CHAPTER 03

Check the dew point

Local air temperature and humidity determine when condensation becomes likely. The team is refining the control that sets the chilled-water temperature.

Second iteration using a slotted metal rack with the cooling unit at its base.

WHAT WE LEARNED

What the team learned

In one documented test at 32 °C and 68% relative humidity, the team compared upper-body surface temperatures before startup and after ten minutes. It recorded a 0.3–0.5 °C decrease across the sampled areas.

PROJECT MILESTONE

Result

Second place in the Residential Cooling Retrofit Product Challenge at Solar Decathlon India 2025–26.